The Home Examiner, LLC
|
|||
Customer |
|||
Home |
|||
Real Estate Agent |
|||
|
|||
Report ID: |
|||
Inspection Date
|
|||
Inspected By
|
|||
The Home Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The home inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The home inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to: Enter any area or perform any procedure that may damage the property or it's components or be dangerous to or adversely effect the health of the home inspector or other persons.
| FOUNDATION: ROCK | METHOD USED TO OBSERVE CRAWLSPACE: CRAWLED | FLOOR STRUCTURE: 2 X 10 WOOD JOISTS |
| WALL STRUCTURE: Not Visible | COLUMNS OR PIERS: WOOD PIERS | CEILING STRUCTURE: NOT VISIBLE |
| ROOF STRUCTURE: 2 X 8 RAFTERS LATERAL BRACING COMMON BOARD | ROOF-TYPE: GABLE |
| 1.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.)
Foundation wall(s) deteriorated at several areas. Repairs are needed. Recommend a skilled masonry contractor perform the work. Foundation wall at right side (facing front) deteriorated and needs repair. Visible signs of water intrusion in crawlspace, basement (left side of home facing front) and (right side of home facing front) are present from water stains on floor. Sloping the ground or trenching may be needed to direct water . Unable to determine the extent of intrusion or how often it occurs . Recommend further investigation by a licensed contractor or water infiltration specialist. White efflorescence (powder substance) on wall indicate moisture is in contact with masonry. This does not necessarily mean that intrusion will occur. Recommend checking gutters, downspout drain lines for proper operation. Also, a water proofing paint could be applied to interior side of block if necessary. Efflorescence is found on many homes without water intrusion occurring inside the home. But, it should alert you to the possibility that future steps may be needed. |
| 1.1 | FLOORS (Structural)
Comments: Inspected |
| 1.2 | WALLS (Structural)
Comments: Inspected |
| 1.3 | COLUMNS OR PIERS
Comments: Inspected |
| 1.4 | CEILINGS (structural)
Comments: Inspected |
| 1.5 | ROOF STRUCTURE AND ATTIC
Comments: Inspected Discovered what appears to be an "old" water sign resulting from a "Roof leak" found at several locations . Leaks appear to be corrected. |
The home inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The home inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The home inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks.The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility.
| SIDING STYLE: LAP WOOD SHAKES | SIDING MATERIAL: WOOD | EXTERIOR ENTRY DOORS: WOOD |
| WINDOW TYPES: AGED DOUBLE-HUNG STORM WINDOWS | APPURTENANCE: BALCONY COVERED PORCH SIDEWALK | |
| OPENER MANUFACTURER: SEARS | GARAGE DOOR MATERIAL: WOOD | TYPE: ONE AUTOMATIC |
| DRIVEWAY: CONCRETE |
| 2.0 | WALL CLADDING FLASHING AND TRIM
Wood trim at right side (facing front) deteriorated, and needs replacing. |
| 2.1 | DOORS (Exterior)
Comments: Inspected, Not Functioning or in Need of Repair Garage door at same location needs prep and paint. |
| 2.2 | WINDOWS
Comments: Inspected Storm windows were not inspected. Glazing between glass panes are failing at some windows. |
| 2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance)
Comments: Inspected Garage Door will reverse when met with resistance. Sensors are in place and will reverse the door. |
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS
Wood floor on Covered porch at rear of home deteriorated, and needs repair or replace. Wrought iron railings on steps at front of home loose at steps, and needs tightening or fastening. |
| 2.5 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building)
Comments: Inspected Negative slope towards right side (facing front). This area does not appear to drain water away from home and needs landscaping and drainage corrected. Trim trees and shrubs to avoid contact with home. Recommend window well covers to help shed water away from foundation. |
| 2.6 | EAVES, SOFFITS AND FASCIAS
Comments: Inspected, Not Functioning or in Need of Repair Bare wood needs primer and paint at left side (facing front). |
The home inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components.The home inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing.The home inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors.
| ROOF COVERING: ASPHALT | VIEWED ROOF COVERING FROM: GROUND | SKY LIGHT (S): NONE |
| CHIMNEY (exterior): BRICK | ROOF PENETRATIONS: PLUMBING VENTS EXHAUST FANS |
| 3.0 | ROOF COVERINGS
Comments: Inspected |
| 3.1 | FLASHINGS
Comments: Inspected |
| 3.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Comments: Inspected, Not Functioning or in Need of Repair Chimney cap is cracked and needs repair. |
| 3.3 | ROOFING DRAINAGE SYSTEMS
Comments: Inspected, Not Functioning or in Need of Repair Gutter is rusted and deteriorated in various areas throughout. Needs replacing. |
The home inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps.The home inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance.The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.
| WATER SOURCE: PUBLIC | WATER FILTERS: (We do not inspect filtration systems) | PLUMBING SUPPLY: AGED GALVANIZED (OLD) |
| DISTRIBUTION: GALVANIZED COPPER | PLUMBING WASTE: PVC CAST IRON (OLD) | WASHER DRAIN SIZE: 2" DIAMETER |
| WATER HEATER POWER SOURCE: GAS | CAPACITY: 40 GAL (1-2 PEOPLE) | MANUFACTURER: NOT VISIBLE |
| 4.0 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS
Comments: Inspected |
| 4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Hot control sink faucet runs very slow at Upstairs Bath. Water pressure was reduced when bath sink faucet and shower was on and toilet was flushed, but it still passed functional flow. Water pressure was reduced when bath sink faucet and shower was on and toilet was flushed, but it still passed functional flow. However temperature changes occurred at shower when toilet or sink was used causing extreme temperature changes from normal to scalding hot. Recommend a plumber to troubleshoot further. Problem could be old galvanized piping. |
| 4.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS
Comments: Inspected |
| 4.3 | MAIN WATER SHUT-OFF DEVICE (Describe location)
Comments: Inspected The main shut-off is the located in basement on front wall (For your info). |
| 4.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks)
Comments: Inspected |
| 4.5 | SUMP PUMP
Comments: Not Present |
The home inspector shall observe: Service entrance conductors; Service equipment, grounding equipment, main overcurrent device, and main and distribution panels; Amperage and voltage ratings of the service; Branch circuit conductors, their overcurrent devices, and the compatibility of their ampacities and voltages; The operation of a representative number of installed ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls; The polarity and grounding of all receptacles within six feet of interior plumbing fixtures, and all receptacles in the garage or carport, and on the exterior of inspected structures; The operation of ground fault circuit interrupters; and Smoke detectors. The home inspector shall describe: Service amperage and voltage; Service entry conductor materials; Service type as being overhead or underground; and Location of main and distribution panels. The home inspector shall report any observed aluminum branch circuit wiring. The home inspector shall report on presence or absence of smoke detectors, and operate their test function, if accessible, except when detectors are part of a central system. The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any overcurrent device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system; or Built-in vacuum equipment.
| ELECTRICAL CONDUCTORS: ABOVE GROUND COPPER 220 VOLTS | PANEL CAPACITY: 100 AMP | PANEL TYPE: CIRCUITS |
| ELEC. PANEL MANUFACTURER: SQUARE D | BRANCH WIRE 15 and 20 AMP: COPPER | WIRING METHODS: ROMEX KNOB AND TUBE |
| NUMBER 15 AMPS: (9) | NUMBER 20 AMPS: (6) |
| 5.0 | SERVICE ENTRANCE CONDUCTORS
Comments: Inspected |
| 5.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS
Comments: Inspected |
| 5.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Older knob and tube wiring observed in basement, recommend an electrician evaluate condition. |
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Comments: Inspected, Not Functioning or in Need of Repair Extension cord used as permanent wiring at front hall. Recommend correct as necessary. "Three-prong" outlets are not grounded. Needs correcting at at end of hall. |
| 5.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE
Comments: Inspected |
| 5.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS)
Comments: Inspected |
| 5.6 | SMOKE DETECTORS
Comments: Not Inspected Smoke detectors were not tested. Recommend replacement of batteries and testing of and detectors upon moving into home. Fire Departments recommend that smoke detectors be replaced every 10 years, ask sellers for age of smoke detectors. |
| 5.7 | LOCATION OF MAIN AND DISTRIBUTION PANELS
Comments: Inspected Main panel box is located at basement on rear wall. |
The home inspector shall observe permanently installed heating systems including: Heating equipment; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The home inspector shall describe: Energy source; and Heating equipment and distribution type.The home inspector shall operate the systems using normal operating controls.The home inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms.
| HEAT TYPE: CIRCULATING BOILER | ENERGY SOURCE: GAS | NUMBER OF HEAT SYSTEMS (excluding wood): ONE |
| HEAT SYSTEM BRAND: UTICA | TYPES OF FIREPLACES: VENTED GAS LOGS | OPERABLE FIREPLACES: ONE |
| 6.0 | HEATING EQUIPMENT
Comments: Inspected |
| 6.1 | NORMAL OPERATING CONTROLS
Comments: Inspected |
| 6.2 | AUTOMATIC SAFETY CONTROLS
Comments: Inspected |
| 6.3 | CHIMNEYS, FLUES AND VENTS
Comments: Inspected |
| 6.4 | SOLID FUEL HEATING DEVICES
Comments: Inspected |
| 6.5 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors)
Comments: Inspected Supply piping for boiler boiler piping is wrapped in possible asbestos. |
| 6.6 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM
Comments: Inspected |
| 6.7 | GAS/LP FIRELOGS AND FIREPLACES
Comments: Inspected |
The home inspector shall observe: Walls, ceiling, and floors; Steps, stairways, balconies, and railings; Counters and a representative number of installed cabinets; and A representative number of doors and windows. The home inspector shall: Operate a representative number of windows and interior doors; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting; or Draperies, blinds, or other window treatments.
| CEILING MATERIALS: PLASTER | WALL MATERIAL: PLASTER | FLOOR COVERING(S): AREA RUG CARPET HARDWOOD T&G TILE |
| INTERIOR DOORS: SOLID RAISED PANEL WOOD | CABINETRY: WOOD | COUNTERTOP: CORIAN |
| 7.0 | CEILINGS
Plaster on ceiling is damaged, and needs repair at upstairs Shared Bath. |
| 7.1 | WALLS
Comments: Inspected |
| 7.2 | FLOORS
Comments: Inspected Recommend silicone caulk along floor and tub at Shared Bath. |
| 7.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Comments: Inspected, Not Functioning or in Need of Repair Hand/guard rail for second story stairs is missing. |
| 7.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Wall cabinetry is pulling away from wall at (right of refrigerator). |
| 7.5 | DOORS (REPRESENTATIVE NUMBER)
Comments: Inspected |
| 7.6 | WINDOWS (REPRESENTATIVE NUMBER)
Comments: Inspected, Not Functioning or in Need of Repair Several windows missing lock hardware and missing sash cords at upstairs and downstairs. |
The home inspector shall observe: Insulation and vapor retarders in unfinished spaces; Ventilation of attics and foundation areas; Kitchen, bathroom, and laundry venting systems; and the operation of any readily accessible attic ventilation fan, and, when temperature permits, the operation of any readily accessible thermostatic control. The home inspector shall describe: Insulation in unfinished spaces; and Absence of insulation in unfinished space at conditioned surfaces. The home inspector shall: Move insulation where readily visible evidence indicates the need to do so; and Move insulation where chimneys penetrate roofs, where plumbing drain/waste pipes penetrate floors, adjacent to earth filled stoops or porches, and at exterior doors. The home inspector is not required to report on: Concealed insulation and vapor retarders; or Venting equipment that is integral with household appliances.
| ATTIC INSULATION: BLOWN BATT FIBERGLASS CELLULOSE | R- VALUE: R-19 OR BETTER | VENTILATION: RIDGE VENTS |
| EXHAUST FAN TYPES: FAN ONLY FAN WITH LIGHT | DRYER POWER SOURCE: GAS CONNECTION | DRYER VENT: FLEXIBLE METAL |
| 8.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces)
Comments: Inspected Cellulose insulation is about seven inches thick or 25.6 R-Value. Fiberglass (Batts) insulation is about six inches thick or just under 19 R-Value. Could not see if all areas of attic are insulated. |
| 8.1 | VENTILATION OF ATTIC AND FOUNDATION AREAS
Comments: Inspected |
| 8.2 | VENTING SYSTEMS (Kitchens, baths and laundry)
Comments: Inspected |
| 8.3 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC)
Comments: Not Present |
The home inspector shall observe and operate the basic functions of the following kitchen appliances: Permanently installed dishwasher, through its normal cycle; Range, cook top, and permanently installed oven; Trash compactor; Garbage disposal; Ventilation equipment or range hood; and Permanently installed microwave oven. The home inspector is not required to observe: Clocks, timers, self-cleaning oven function, or thermostats for calibration or automatic operation; Non built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.
| DISHWASHER: GENERAL ELECTRIC | DISPOSER: IN SINK ERATOR | EXHAUST/RANGE HOOD: JENN AIR |
| RANGE/OVEN: JENN AIR | REFRIGERATOR: AMANA |
| 9.0 | DISHWASHER
Comments: Inspected |
| 9.1 | RANGES/OVENS/COOKTOPS
Comments: Inspected |
| 9.2 | RANGE HOOD
Comments: Inspected |
| 9.3 | TRASH COMPACTOR
Comments: Not Present |
| 9.4 | FOOD WASTE DISPOSER
Comments: Inspected |
| 9.5 | MICROWAVE COOKING EQUIPMENT
Comments: Not Present |
![]()
The Home Examiner, LLC |
|
Customer |
|
Home |
|
This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function, efficiency, or safety of the home.
This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report.
EXTERIOR
| 2.0 | WALL CLADDING FLASHING AND TRIM
Inspected, Not Functioning or in Need of Repair Wood trim at right side (facing front) deteriorated, and needs replacing. |
| 2.1 | DOORS (Exterior)
Inspected, Not Functioning or in Need of Repair Garage door at same location needs prep and paint. |
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS
Inspected, Not Functioning or in Need of Repair Wood floor on Covered porch at rear of home deteriorated, and needs repair or replace. Wrought iron railings on steps at front of home loose at steps, and needs tightening or fastening. |
| 2.6 | EAVES, SOFFITS AND FASCIAS
Inspected, Not Functioning or in Need of Repair Bare wood needs primer and paint at left side (facing front). |
ROOFING
| 3.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS
Inspected, Not Functioning or in Need of Repair Chimney cap is cracked and needs repair. |
| 3.3 | ROOFING DRAINAGE SYSTEMS
Inspected, Not Functioning or in Need of Repair Gutter is rusted and deteriorated in various areas throughout. Needs replacing. |
PLUMBING SYSTEM
| 4.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES
Inspected, Not Functioning or in Need of Repair Hot control sink faucet runs very slow at Upstairs Bath. Water pressure was reduced when bath sink faucet and shower was on and toilet was flushed, but it still passed functional flow. Water pressure was reduced when bath sink faucet and shower was on and toilet was flushed, but it still passed functional flow. However temperature changes occurred at shower when toilet or sink was used causing extreme temperature changes from normal to scalding hot. Recommend a plumber to troubleshoot further. Problem could be old galvanized piping. |
ELECTRICAL SYSTEMS
| 5.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE
Inspected, Not Functioning or in Need of Repair Older knob and tube wiring observed in basement, recommend an electrician evaluate condition. |
| 5.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls)
Inspected, Not Functioning or in Need of Repair Extension cord used as permanent wiring at front hall. Recommend correct as necessary. "Three-prong" outlets are not grounded. Needs correcting at at end of hall. |
INTERIORS
| 7.0 | CEILINGS
Inspected, Not Functioning or in Need of Repair Plaster on ceiling is damaged, and needs repair at upstairs Shared Bath. |
| 7.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS
Inspected, Not Functioning or in Need of Repair Hand/guard rail for second story stairs is missing. |
| 7.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS
Inspected, Not Functioning or in Need of Repair Wall cabinetry is pulling away from wall at (right of refrigerator). |
| 7.6 | WINDOWS (REPRESENTATIVE NUMBER)
Inspected, Not Functioning or in Need of Repair Several windows missing lock hardware and missing sash cords at upstairs and downstairs. |
Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Home inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
| The Home Examiner, LLC 616-776-7725 |
259 Morris Ave. S.E. Grand Rapids, MI 49503 |
INSPECTION AGREEMENT
(Please read carefully)
THIS AGREEMENT is made and entered into by and between THE HOME EXAMINER, LLC referred to as “Inspector”, and Victorian Morehouse , referred to as “Client”.
In consideration of the promise and terms of this Agreement, the parties agree as follows:
1. The client will pay the sum of $
400.00
for the inspection of the “Property”, being the residence, and garage or carport, if applicable, located at
Grand Rapids, Michigan, , MI
.
2. The
Inspector will perform a visual inspection and prepare a report of the
apparent condition of the
readily accessible installed system and components of the property existing
at the time of the inspection. Latent and concealed defects and deficiencies
are excluded from the inspection.
3. The
parties agree that the “Standard of Practice” (the “Standards”) shall define
the standard
of duty and the conditions, limitation, and exclusion of the inspection
and are incorporated by reference herein.
4. The
parties understand and agree that the Inspector and its employees and its
agent assume no
liability or responsibility for the costs of repairing or replacing any
unreported defects or deficiencies either current or arising in the future
or any property damage, consequential damage or bodily injury of any nature.
If repairs or replacement is done without giving the Inspector the required
notice, the Inspector will have no liability to the Client. The client
further agrees that the Inspector is liable only up to the cost of the
inspection.
5. The
parties agree and understand the Inspector is not an insurer or guarantor
against defects
in the structure, items, components or system inspected. INSPECTOR MAKES
NO WARRANTY, EXPRESS OR IMPLIED AS TO THE FITNESS FOR USE, CONDITION, PERFORMANCE
OR ADEQUACY OF ANY INSPECTED STRUCTURE, ITEM, COMPONENT, OR SYSTEM.
6. If
Client is married, Client represents that this obligation is a family obligation
incurred
in the interest of the family.
7. This
Agreement, including the terms and conditions listed below, represents the
entire agreement
between the parties and there are no other agreements either written or
oral between them. This Agreement shall be amended only by written agreement
signed by both parties. This Agreement shall be construed and enforced
in accordance with the laws of the State of Michigan.
8. Systems,
items, and conditions which are not within the scope of the building inspection
include,
but are not limited to: formaldehyde, lead paint, asbestos, toxic or flammable
materials, molds, fungi, other environmental hazards; pest infestation;
security and fire protection systems; humidifiers; paint, wallpaper and
other treatment to windows, interior walls, ceilings and floors; recreational
equipment or facilities; underground storage tanks, energy efficiency measurements;
concealed or private secured systems; water wells; heating systems accessories;
solar heating systems; heat exchangers; sprinkling systems; water softener;
central vacuum systems, telephone, intercom or cable TV systems; antennae,
lightning arrestors; trees or plants; governing codes, ordinances, statutes
and covenants and manufacturer specifications, recalls, EIFS. Client understands
that these systems, items and conditions are excepted from this inspection. Any general comments about
these systems, items and conditions of the report are informal only and
DO NOT represent an inspection.
9. The
inspection and report are performed and prepared for the sole and exclusive
use and possession
of the Client. No other person or entity may rely on the report issued
pursuant to this Agreement. In the event that any person, not a party to
this Agreement, makes any claim against Inspector, its employees or agents,
arising out of the services performed by Inspector under this Agreement,
the Client agrees to indemnify, defend and hold harmless Inspector from
any and all damages, expenses, costs, and attorney fees arising from such
a claim.
10. The Inspection
will not include an appraisal or the value or a survey. The written report
is not a compliance
inspection or certification for past or present governmental codes or regulations
of any kind.
11. In the
event of a claim by the Client that an installed systems or component of
the premises which was inspected by the Inspector was not in the condition
reported by the Inspector, the Client agrees to notify the Inspector at
least 72 hours prior to repairing or replacing such system or component.
The Client further agrees that the Inspector is liable only if there has
been a complete failure to follow the standards adhered to in the report
or State law. Furthermore, any legal action must be brought within two
(2) years from the date of the inspection, or will be deemed waived and
forever barred.
12. This inspection does not determine whether the property is insurable.
Client has read this entire Agreement and
accepts and understands this Agreement as hereby acknowledged.
This report adheres to the NAHI Standards,
which is available upon request.
Client’s signature: __________________________________________________ Date: _______________
Client’s signature: __________________________________________________ Date: _______________
Client's Current Street Address: Grand Rapids, MI
City/State/Zip: MI
Inspector’s Signature _________________________________________________ Date: _______________
Client authorizes Inspector to release reports
to
Client's REALTOR® - Yes ___ No ___
Seller’s
REALTOR® - Yes ___ No ___
| Customer: Victorian Morehouse |
| Location: Grand Rapids, Michigan , MI |
| Inspection Date: Saturday, August 16, 2003 |
| Report ID: 081603A |
Inspection Fee:
| ||||||||||||
Tax $0.00 | ||||||||||||
| Total Price $400.00 |
Payment Options:
| X | Paid In Full | |
| Customer to send payment |
Grand Rapids, MI MI |
|
| To Be Paid At Closing |
Attorney: Projected Closing Date: |